Flask

Scientific & Medical
Products Ltd

Logo
search

Dynamic Mechanical Analyser




EXSTAR6000 DMS/DMA Series

  • Variety of Deformation modes
  • Tension, Dual Cantilever Bending, Compression and Shear
  • Thermal Expansion Correction
  • Single Fibre to Stiff Bulk Sample Measurements
  • Unsurpassed Temperature Control
 

The advanced design of EXSTAR DMS 6100 DMS features the large force range up to 18 N, which allows the handling of a wide range of sample configurations and stiffness ranging from single fibres and films to thick reinforced composites. The instrument covers the unbelievable modulus range from 10³ to 10¹² Pa.

Synthetic Oscillation Mode

This measurement mode is SIINT original technology, which is applied a complex wave form with different frequencies to the sample and provides a series measurement results simultaneously. Synthetic Oscillation mode speeds up not the measurement and analysis only, but also useful in measuring samples with high modulus changes as a function of temperature using high scan rates (5 to 10°C/min.)

Fourier Transform Technology

Since the instrument uses the Fourier transform technology to reduce the signal deformation noise, it provides the best possible signal to noise resolution for the detection of very weak transitions. With increasing the data processing speed, more accurate viscoelastic data can be obtained very easily.

DSC6300

Designed with the high temperature, high sensitivity sensor and the unique gas exchange system it guarantees the desired atmosphere up to 1500°C. It is the best equipment to analyse metal and ceramic samples.

Thermal Expansion Correction Function

It is very difficult to detect the strain signal correctly due to the effect of the static deformations caused by thermal expansion, creep etc. The EXSTAR 6000 DMS is equipped with a high sensitive sensor and drive the high accuracy stepping motor to correct for any sample dimensions changes. It precisely controls the sample starin during any phase of a measurement. This provides high accurate easurements with unsurpassed correct modulus and tan delta values.

Wide Measurement Range

EXSTAR 6000 DMS features advanced auto tension control technology to provide continuous data on different samples such as samples with a large drop in modulus and significantly stretch at temperatures above the glass transition. The sophisticated auto tension control function allows the EXSTAR DMS 6000 to measure the different type of samples ranging from very stiff to very soft very easily.

Bending Tension Shear Film Shear Compression 3 Point Bending
Measurement Modes: Dynamic Measurements: Sine Wave 0.01-100 Hz /Synthetic Oscillation – Static Measurements: Program Stress Strain Control / Program Strain Control
Frequency: 0.01-100 Hz 0.01-100 Hz 0.01-100Hz 0.01-100 Hz 0.01-100 Hz 0.01-100 Hz
Measurement Range: 10exp.5 - 10exp.12 Pa 10exp.5 - 10exp.12 Pa 10exp.3 - 10exp.9 Pa 10exp.7 - 10exp.11 Pa 10exp.5 - 10exp.9 10exp.5 - 10exp.12 Pa
Temperature Range: -150 – 600°C -150 – 600°C -150 – 600°C -150 – 600°C -150 – 600°C -150 – 600°C
Program Heating Rate: 0.01 – 20°C/min. 0.01 – 20°C/min. 0.01 – 20°C/min. 0.01 – 20°C/min. 0.01 – 20°C/min. 0.01 – 20°C/min.
Sample Dimensions: Length: 50 mm
Thickness: 5 mm
Width: 16 mm
Length: 5 - 35 mm
Thickness: 3 mm
Width: 10 mm
Cross Section: 10 mm²
Thickness: 7 mm
Length: 50 mm
Thickness: 0.5 mm
Width: 10 mm
Length: 15 mm
Diameter: 10 mm
Length: 50 mm
Thickness: 5 mm
Width: 16 mm
     
Shirley House,   12 Gatley Road,   Cheadle,   Cheshire,   SK8 1PY.    T: +44 (0) 161 491 3068    E: enquiries@scimed.co.uk