ICprep-series

ICprep Series

The ICprep performs automated AOF/EOF/TOF Sample Preparation for Fluorine analysis; this provides initial PFAS screening data.

Product Overview

The ICprep automated sample handling system from Analytik Jena is designed for laboratories measuring fluorine that require reliable, high-throughput preparation of complex samples for both ion chromatography and combustion-based workflows.

Compliance with EPA 1621 ensures a simple approach for PFAS screening.

With integrated automated pyrohydrolytic combustion, dynamic matrix switching, and compatibility with multi-detector systems, the ICprep Series ensures accurate and standards-compliant results. Ideal for environmental and industrial labs, it boosts reproducibility while reducing manual workload.

Whether measuring AOF, TOF, EOF or TF, and regardless of sample matrix the ICprep will prepare your sample for analysis.

Features & Benefits

ICprep-series

Flexible Sample Compatibility

Handles solids, liquids, and complex matrices with minimal setup.

Combustion Technology You Can Trust

Flame sensor-guided combustion ensures complete oxidation and safety.

Built for Compliance

Meets major international standards (DIN, EPA, ASTM).

Seamless System Integration

Works directly with downstream IC, ISE, and photometric detectors.

Key applications of ICprep Series

  • Fully automated AOF/EOF/TOF sample preparation
  • High-throughput operation with fraction collection
  • Supports liquid and solid samples
  • Integrated flame sensor combustion technology
  • Compatible with IC, ISE and photometry detectors
  • Customisable multi-matrix sampler (MMS)
  • Automatic Boat Drive combustion for solid matrices
  • Optimised for DIN, EPA, and ASTM compliance
  • Seamless integration with Analytik Jena’s APU Series
  • Includes column adsorption/SPE for aqueous sample prep
  • EPA 1621 compliant
  • Provides a screening methodology for PFAS analysis. 

ICprep Series: AOF Sample Preparation for Ion Chromatography and More

About the ICprep Series

In modern analytical laboratories, handling varied sample matrices without sacrificing throughput or compliance remains a key challenge. The ICprep Series addresses this by delivering a robust, fully automated solution tailored for AOF, AOX, EOF, TOF and other combustion-based analyses. Whether you’re testing soil, wastewater, or process chemicals, the ICprep enables streamlined workflows that cut down manual handling while boosting data consistency.

The system features automated pyrohydrolytic combustion, designed to effectively break down fluorine compounds into measurable analytes.

The integrated flame sensor technology continuously monitors the combustion process to ensure complete sample oxidation. With liquid/solid switching, the system eliminates the need for separate hardware or lengthy changeovers.

At the heart of the ICprep Series is its multi-matrix sampler (MMS), allowing laboratories to process a broad range of samples in one run. Combined with automatic boat drive combustion and fraction collection, this ensures the highest level of reproducibility across varying workloads.

Applications extend across:

  • Environmental testing labs conducting regulatory compliance for AOX/EOF in surface and groundwater
  • Industrial labs verifying chemical content and contaminants in manufacturing processes
  • Government or contract labs supporting high-volume, standards-aligned sample workflows

Unique to ICprep is its compatibility with APU series sample prep units and downstream detection via ion chromatography (IC), ion-selective electrodes (ISE), and photometric systems. This end-to-end integration ensures continuity in data acquisition and removes the error-prone manual transfer step.

Compared to traditional setups, ICprep drastically reduces labour input, lowers per-sample cost, and improves traceability, making it a reliable asset for organisations driven by quality, safety, and regulatory compliance.

"The ICPREP series is a compact, fully automated system for precise,
high-throughput sample preparation for ICP spectroscopy."

Product FAQ's

ICprep is used to automatically prepare samples (solid or liquid) for analysis of AOX, AOF, EOF, and TOF. It complies with EPA 1621.

Yes, ICprep offers automated switching between liquid and solid samples, ideal for labs dealing with complex or mixed matrices.

Absolutely. The system is fully compliant with EPA 1621, DIN EN 1485, EPA 9020, and ASTM D808 methods for halogen and organofluorine detection.

The system supports a range of detectors including ion chromatography, ISE, and UV/Vis photometry, ensuring flexible downstream analysis.

ICprep features automated boat handling, multi-matrix capability, and fraction collection, allowing it to process multiple samples efficiently with minimal user input.