Gamry RxE 10k accessory

Gamry Rotating Electrode

Research-grade rotator featuring the ability to use rotating ring-disk, disk, and cylinder electrodes

Summary

The RxE 10k Rotating Electrode is a versatile research grade electrochemical rotator that supports disk, ring disk, and cylinder electrode experiments with precise speed control, enabling accurate mass transport studies across applications such as corrosion testing, catalyst development, and fuel cell research.

Product Overview

The RxE 10k Rotating Electrode can be used as the working electrode in any electrochemical cell with any Gamry potentiostat. The RxE is digital (USB) or analog controlled. Rotation rates are 50-10500 rpm. The RxE accuracy over this rotation rate range is +/- 1rpm.

Features & Benefits

Gamry RxE 10k accessory

High accuracy

Rotation rate accuracy +/- 1rpm

High rotation rate

50-10500 rpm

Use with any Gamry potentiostat

Including Reference 620, Reference 3020, Interface 1010, Interface 5000

Multiple electrode compatibility

Rotating ring-disk, rotating disk, cylindrical

Analog and digital control

Gamry Rotating Electrode

  • High rotation rate
  • High accuracy
  • Use with any Gamry potentiostat
  • Multiple electrode type compatibility
  • Analog and digital control

Latest Videos

Playlist

3 Videos

About the Product - Gamry Rotating Electrode

Precision Rotation Control and Electrode Versatility

The RxE 10k Rotating Electrode is a research-grade rotator and features the ability to use rotating ring-disk, disk, and cylinder electrodes. The rotation rate is adjustable from 50 – 10500 rpm (revolutions per minute).

The Controller has a Liquid Crystal Display (LCD) which indicates the rotation rate and is controlled by a rotation rate knob. Alternatively, the rotation rate may be controlled by your Gamry Interface or Reference family instrument.

The electrode assembly of the rotator has a versatile design that allows for the use of diverse electrode types. Different shaft and electrode tips can be selected depending on your desired use. Different shafts are used for disk and cylinder or ring–disk experiments.

Applications

  • Corrosion
  • Catalyst Development
  • Fuel Cell Research
  • Controlling Mass Transport of Reactants to Electrode Surface

 

Rotating ring-disk electrodes are used where products generated at the disk electrode are monitored at the ring electrode.

A bipotentiostat is required for these experiments and Gamry can supply an instrument using two standard Gamry Potentiostats collecting data synchronously when connected to the same computer. A number of ring-disk electrodes are available including platinum-platinum, gold-gold and glassy carbon-glassy carbon.

Rotating disk experiments are performed where defined mass transport to the sample electrode is desired. An example of this type of experiment would be catalyst evaluation.

Rotating Cylinder Experiments and Electrode Material Options

Rotating cylinder experiments are important in the oil industry to simulate the corrosion environment inside a pipeline, thus avoiding the need to assemble expensive flow loop setups.

The rotator is an ideal tool because flow conditions at the rotating cylinder are generally turbulent even at low rotation rates.

Cylinders can be made from a variety of different metals to evaluate their performance including 1018 carbon steel, 316 stainless steel and 430 stainless steel. Users can machine cylinder samples using their actual material.

The electrodes for the rotator are sold separately and include a wide selection of standard materials such as gold, platinum, glassy carbon, carbon steel, stainless steel, etc. Custom materials are available on request.

Compatible Rotating Electrode Configurations Table

Mode

Electrode

Rotating Disk Electrode

Au
Pt
GC

Rotating Ring-Disk Electrode

GC-GC
GC-Pt (disk-ring)
Pt-Pt

Au-Au

Rotating Cylinder

1018 carbon steel
430 SS
316 SS

'The RxE 10k Rotating Electrode provides precise, adjustable rotation for disk, ring disk, and cylinder electrochemical experiments across a wide range of research applications.'

Product FAQ's

The RxE 10k is used to precisely control electrode rotation during electrochemical experiments, enabling accurate mass transport studies for applications such as corrosion testing, catalyst evaluation, and fuel cell research.

The system supports rotating disk, rotating ring disk, and rotating cylinder electrodes, allowing flexibility for a wide range of experimental setups.

The rotation speed is adjustable from 50 to 10500 rpm, providing fine control across both low and high speed experimental conditions.

The RxE maintains a rotational accuracy of ±1 rpm across its operating range, ensuring highly repeatable experimental results.

Yes. The RxE can be controlled directly through its onboard controller or through compatible Gamry instruments using digital or analog control.

Application Notes



Contact Us Today

We take great pleasure in assisting you and ensuring you get a prompt response to your questions

Live chat opening hours Mon – Fri 9:15 to 16:30 (UK Time)

Request a Call Back

Please refer to our Privacy statement for information on how SciMed uses your details.
Back to Menu