Summary
The RxE 10k Rotating Electrode is a versatile research grade electrochemical rotator that supports disk, ring disk, and cylinder electrode experiments with precise speed control, enabling accurate mass transport studies across applications such as corrosion testing, catalyst development, and fuel cell research.
Product Overview
The RxE 10k Rotating Electrode can be used as the working electrode in any electrochemical cell with any Gamry potentiostat. The RxE is digital (USB) or analog controlled. Rotation rates are 50-10500 rpm. The RxE accuracy over this rotation rate range is +/- 1rpm.
Features & Benefits
High accuracy
Rotation rate accuracy +/- 1rpm
High rotation rate
50-10500 rpm
Use with any Gamry potentiostat
Including Reference 620, Reference 3020, Interface 1010, Interface 5000
Multiple electrode compatibility
Rotating ring-disk, rotating disk, cylindrical
Analog and digital control
Gamry Rotating Electrode
- High rotation rate
- High accuracy
- Use with any Gamry potentiostat
- Multiple electrode type compatibility
- Analog and digital control
Latest Videos
Playlist
1:49
3:01
About the Product - Gamry Rotating Electrode
Precision Rotation Control and Electrode Versatility
The RxE 10k Rotating Electrode is a research-grade rotator and features the ability to use rotating ring-disk, disk, and cylinder electrodes. The rotation rate is adjustable from 50 – 10500 rpm (revolutions per minute).
The Controller has a Liquid Crystal Display (LCD) which indicates the rotation rate and is controlled by a rotation rate knob. Alternatively, the rotation rate may be controlled by your Gamry Interface or Reference family instrument.
The electrode assembly of the rotator has a versatile design that allows for the use of diverse electrode types. Different shaft and electrode tips can be selected depending on your desired use. Different shafts are used for disk and cylinder or ring–disk experiments.
Applications
- Corrosion
- Catalyst Development
- Fuel Cell Research
- Controlling Mass Transport of Reactants to Electrode Surface
Rotating ring-disk electrodes are used where products generated at the disk electrode are monitored at the ring electrode.
A bipotentiostat is required for these experiments and Gamry can supply an instrument using two standard Gamry Potentiostats collecting data synchronously when connected to the same computer. A number of ring-disk electrodes are available including platinum-platinum, gold-gold and glassy carbon-glassy carbon.
Rotating disk experiments are performed where defined mass transport to the sample electrode is desired. An example of this type of experiment would be catalyst evaluation.
Rotating Cylinder Experiments and Electrode Material Options
Rotating cylinder experiments are important in the oil industry to simulate the corrosion environment inside a pipeline, thus avoiding the need to assemble expensive flow loop setups.
The rotator is an ideal tool because flow conditions at the rotating cylinder are generally turbulent even at low rotation rates.
Cylinders can be made from a variety of different metals to evaluate their performance including 1018 carbon steel, 316 stainless steel and 430 stainless steel. Users can machine cylinder samples using their actual material.
The electrodes for the rotator are sold separately and include a wide selection of standard materials such as gold, platinum, glassy carbon, carbon steel, stainless steel, etc. Custom materials are available on request.
Compatible Rotating Electrode Configurations Table
Mode | Electrode |
Rotating Disk Electrode | Au |
Rotating Ring-Disk Electrode | GC-GC Au-Au |
Rotating Cylinder | 1018 carbon steel |
'The RxE 10k Rotating Electrode provides precise, adjustable rotation for disk, ring disk, and cylinder electrochemical experiments across a wide range of research applications.'
Product FAQ's
The RxE 10k is used to precisely control electrode rotation during electrochemical experiments, enabling accurate mass transport studies for applications such as corrosion testing, catalyst evaluation, and fuel cell research.
The system supports rotating disk, rotating ring disk, and rotating cylinder electrodes, allowing flexibility for a wide range of experimental setups.
The rotation speed is adjustable from 50 to 10500 rpm, providing fine control across both low and high speed experimental conditions.
The RxE maintains a rotational accuracy of ±1 rpm across its operating range, ensuring highly repeatable experimental results.
Yes. The RxE can be controlled directly through its onboard controller or through compatible Gamry instruments using digital or analog control.
Application Notes
Application Notes 1
Gamry Rotating Electrode
DOWNLOAD NOTESApplication Notes 2
Gamry Rotating Electrode
DOWNLOAD NOTES
Contact Us Today
We take great pleasure in assisting you and ensuring you get a prompt response to your questions
Live chat opening hours Mon – Fri 9:15 to 16:30 (UK Time)